MS25269L
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operating cycles x 103 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
100 3/ |
5 |
5 |
5 |
4 |
||||||||
Inductive |
100 3/ |
||||||||||||
Inductive |
20 3/ |
3 |
3 |
3 |
2 |
||||||||
Motor |
100 3/ |
1.5 |
1.5 |
1.5 |
1 |
||||||||
Lamp |
100 3/ |
0.8 |
0.8 |
0.8 |
0.6 |
||||||||
Transfer load 2/ |
|||||||||||||
Mechanical life (reduced current) |
400 3/ |
1.25 |
1.25 |
1.25 |
1 |
||||||||
Mixed loads |
Applicable in accordance with MIL-PRF-6106 |
1/ Absence of value indicates the relay is not rated for 3 phase application.
2/ Transfer load indicates the relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.
3/ MS25269-A1 is rated for 50,000 cycles, except that inductive is 10,000 cycles and mechanical life is 200,000
cycles.