MS25205G
Inches |
mm |
Inches |
mm |
.005 |
0.13 |
1.125 |
28.58 |
.094 |
2.39 |
1.230 |
31.24 |
.175 |
4.45 |
1.500 |
38.10 |
.180 |
4.57 |
2.000 |
50.80 |
.188 |
4.78 |
2.230 |
56.64 |
.200 |
5.08 |
2.500 |
63.50 |
.218 |
5.54 |
2.562 |
65.07 |
.250 |
6.35 |
2.594 |
65.89 |
.260 |
6.60 |
2.640 |
67.06 |
.375 |
9.52 |
2.750 |
69.85 |
.380 |
9.65 |
2.940 |
74.68 |
.500 |
12.70 |
3.000 |
76.20 |
.562 |
14.27 |
3.120 |
79.25 |
.625 |
15.88 |
3.375 |
85.72 |
.688 |
17.48 |
3.500 |
88.90 |
.750 |
19.05 |
3.750 |
95.90 |
.870 |
22.10 |
4.000 |
101.60 |
.880 |
22.35 |
4.500 |
114.30 |
1.000 |
25.40 |
5.375 |
136.52 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is .010 (0.25 mm).
4. The flasher need not have the shape shown, but shall be contained within the outline shown.
5. Allowable voltage variation shall be in accordance with MIL-F-26301.
6. Allowable frequency variation is ±5.0 percent of rated frequency.
7. Flash rate shall be 90 ±10 flashes per minute.
8. The voltage drop within the flasher shall not exceed 5.0 percent of the input voltage for any value of load within the limits specified in MIL-F-26301.
9. MS25205-1, -3, -6, and -8 through -11 are canceled without replacement.
10. MS25205-2 is superseded by MS24577-4.
11. MS25205-4 is superseded by MS24577-2A.
12. Classes A, B, K, R, and F of MS3106 are inactive for new design.
13. MS3106E is canceled. For existing designs use MS3106F for connectors with clamp and MS3106R for connectors with grommet seal.
FIGURE 1. Dimensions and configuration - Continued.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.