MS25035E
Inches |
mm |
Inches |
mm |
.005 |
0.013 |
1.000 |
25.40 |
.020 |
0.51 |
1.250 |
31.75 |
.060 |
1.52 |
1.375 |
34.92 |
.173 |
4.39 |
1.687 |
42.85 |
.188 |
4.78 |
2.625 |
66.68 |
.531 |
13.49 |
2.666 |
67.72 |
.562 |
14.27 |
3.000 |
76.20 |
.625 |
15.88 |
3.218 |
81.74 |
.750 |
19.05 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance are ±.010 (0.025 mm).
FIGURE 1. Configurations and dimensions - Continued.
REQUIREMENTS
Operating cycles: 50,000 minimum. Contact data:
Contact voltage drop: Not applicable
Load ratings: See Table I.
TABLE I - Rated contact load (per pole).
Type of load |
Amperes |
Resistive (DC) |
25 |
Resistive (AC 400 Hz, 115 volts) |
25 |
Inductive (28 V dc) |
20 |
Motor (28 V dc or 115 V ac, 400 Hz) |
25 |
Mixed loads MS25024-2 |
See MIL-PRF-6106. |
Overload current: Not applicable.
Rupture current: Not applicable.