MS24376P
REQUIREMENTS:
Dimensions and configurations: See figure 1. ENVIRONMENTAL CHARACTERISTICS:
Temperature range: -70°C to +125°C for de operated relays; -70°C to+ 71 °C for ac operated
relays.
Maximum altitude rating: 80,000 feet
Shock g-level: 25 g's.
Duration: 6 ms to 9 ms.
Maximum duration contact opening: 2 ms. Vibration, sinusoidal: See table I.
Vibration, random: Not applicable. High shock: Not applicable. Acceleration: 15 g's.
ELECTRICAL CHARACTERISTICS (see table II, table Ill, and table IV): Insulation resistance, initial: 100 megohms.
After life or environmental tests: 50 megohms.
Dielectric strength (sea level): 2 seconds to 5 seconds.
Initial 11
After life tests 11
Coil to case |
28 V de 1,250 V rms |
115 V ac 1,500 |
28 V de 1,000Vrms |
115 V ac 1,125 |
Aux contacts |
1,250 V rms |
1,500 |
1,000 V rms |
1,125 |
All other points |
1,250 V rms |
1,800 |
1,000 V rms |
1,350 |
Dielectric strength (altitude) (80,000 feet): 1 minute. ';,/
28 V de 11 115 V ac 11
Coil to case |
500 V rms |
500 |
Aux contacts |
500 V rms |
500 |
All other points |
700 V rms |
500 |
11 For A 1, A2, A3, and A4, coil terminals X 1 and X2 must be shorted together for all dielectric testing between coil to case, coil to main or auxiliary contacts, and coil to all other points.
® ';,./ Use MS27243-1 terminal cover during dielectric testing at altitude.
3
Source: https://assist.dla.mil -- Downloaded: 2014-09-27T06:40Z Check the source to verify that this is the current version before use.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business