MS24185M
Shock g-level: 25 g's. Duration: 6-9 ms.
Maximum duration contact opening: 2 ms. Vibration - sinusoidal: See table IV.
Vibration - random: N/A. High shock: N/A. Acceleration: 10 g's.
Qualification by similarity: See MIL-PRF-6106.
Part or Identifying Number (PIN): MS24185- (plus applicable dash number from table I).
TABLE I. PIN and general characteristics.
Part number MS24185- |
Type |
Coil type |
Terminal type |
Mounting or mating socket |
Maximum weight in pounds |
D1 1/ 3/ |
II |
dc |
Stud |
Bracket - bottom |
2.6 |
D2 2/ 3/ |
II |
dc |
Stud |
Bracket - side |
2.6 |
1/ For Government logistics support, MS24185-D1 shall be used in lieu of AN3380-2.
2/ For Government logistics support, MS24185-D2 shall be used in lieu of AN3380-1.
3/ For similar relays with transient suppressed coils see MIL-PRF-6106/56.
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 1/ |
See appro- priate notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
50 |
400 |
||||||||||||
Inductive |
10 |
100 |
||||||||||||
Motor |
50 |
400 |
||||||||||||
Lamp |
||||||||||||||
Transfer load |
2/ |
|||||||||||||
Mechanical life reduced current |
100 |
100 |
||||||||||||
Mixed loads |
50 |
40 |
1/ Absence of value indicates parameter is not applicable to this specification sheet.
2/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at the rating indicated.