MS24183L
REQUIREMENTS:
Dimensions and configurations: See figure 1. PIN's and general characteristics: See table I. Contact data:
Load ratings: See table II. Maximum contact drop:
Initial: 0.150 volt.
After life test: 0.175 volt.
Overload current (NO): 1,600 amperes. Rupture current (NO): 2,000 amperes.
Coil data: See table III. Duty rating: Continuous.
Electrical data:
Minimum insulation resistance: Initial: 100 megohms.
After life or environmental test: 50 megohms.
Dielectric strength: Sea level, 2-5 seconds:
Initial |
After life tests |
|||
28 V dc |
115 V ac |
28 V dc |
115 V ac |
|
Coil to case |
1,250 V rms |
1,500 V rms |
1,000 V rms |
1,125 |
All other points |
1,250 V rms |
1,500 V rms |
1,000 V rms |
1,125 |
Dielectric strength (altitude): 1 minute.
28 V dc |
115 V ac |
|
Coil to case |
500 V rms |
500 V rms |
All other points |
500 V rms |
500 V rms |
Environmental characteristics: Temperature range: -70°C to + 71°C. Max altitude rating: 80,000 feet. Shock, g-level: 25 g's.
Duration: 6-9 ms.
Maximum duration contact opening: 2 ms.
3