MS24182L
Shock, g-level: 25 g's. Duration: 6-9 ms.
Maximum duration contact opening: 2 ms. Vibration, sinusoidal: See table IV.
Acceleration: 15 g's.
Part or Identifying Number (PIN): MS24182-D1.
TABLE I. Dash number and general characteristics. 1/
PIN MS24182- |
Type |
Coil |
Terminal type |
Mounting or mating socket |
Auxiliary contacts |
Max weight (pounds) 2/ |
D1 |
I |
dc |
Stud |
Flange |
None |
1.15 |
TABLE II. Rated contact load (amperes per pole) case grounded. 1/
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 2/ |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
50 |
100 |
100 |
5 |
|||||||||
Inductive |
10 |
100 |
5 |
||||||||||
Motor |
50 |
100 |
75 |
||||||||||
Lamp 3/ |
50 |
50 |
50 |
.75 |
|||||||||
Transfer load 4/ |
|||||||||||||
Mechanical life reduced current |
100 |
25 |
1.25 |
||||||||||
Mixed loads |
50 |
10 |
10 |
1/ Absence of value indicates parameter is not applicable to this specification sheet.
2/ Absence of value indicates relay is not rated for three phase applications.
3/ The total "On" time shall be 2 seconds ±0.05 second and the "Off" time shall be 7 seconds ±2.0 seconds for a simulated lamp load.
4/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business