MS24179N
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.062 (1.57 mm).
4. Additional flat washer may be used for terminal seat.
5. Terminal temperature rise under continuous current conditions shall be 95°C. Mixed loads shall be conducted at 71°C.
6. In the event of a conflict between the text of this document and the references cited herein, the text of
this document shall take precedence.
7. Referenced Government documents of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicitation form a part of this document to the extent specified herein.
8. Shape of relay is optional within the envelope dimensions shown.
9. Cadmium or cadmium compounds are prohibited on external hardware. A transition period to non- cadmium hardware is authorized for up to 1 year from the date of this revision.
10. Spring washer on drawing is a spring lock washer.
FIGURE 1. Dimensions and configurations - Continued.
REQUIREMENTS:
Dimensions and configurations: See figure 1.
Dash number and general characteristics: See table I. Contact data:
Load ratings: See table II.
Maximum contact drop, initial: 0.175 V. After life test: 0.200 V.
Overload current (N.O.): 3,200 amperes. Rupture current (N.O.): 4,000 amperes.
Coil data: See table III. Duty rating: Intermittent.
Electrical data:
Minimum insulation resistance: Initial: 100 megohms.
After life or environmental test: 50 megohms.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business