MS24178H
TABLE III. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operat ing cycles 3 x 10 |
28 V dc |
115 V ac, 1 phase |
115/200 V ac, 3 phase 3/ |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
||
Resistive |
50 |
55 |
55 |
||||||||||
Inductive |
10 |
40 |
|||||||||||
Inductive |
|||||||||||||
Motor |
50 |
40 |
35 |
||||||||||
Lamp |
|||||||||||||
Transfer load |
2/ |
||||||||||||
Mechanical life reduced current |
100 |
14 |
|||||||||||
Mixed loads |
50 |
5 |
NOTES, APPLICATION
1/ Over temperature range.
2/ With nominal coil voltage.
3/ Absence of value indicates relay is not rated for 3 phase applications.
Electrical characteristics:
Temperature range -55°C to +71°C Maximum altitude rating 50,000 ft
Shock G-level 25 g's Duration 6-9 ms Max duration contact opening 2 ms
Vibration - sinusoidal (see table IV)
TABLE IV. Vibration levels.
Dash number |
5-10 Hz |
10-55 Hz |
55-250 Hz |
250-500 Hz |
500-1,500 Hz |
D1 |
.08 DA |
.06 DA |
2 g's |
2 g's |
Vibration - Random Applicable spec Power spectral density Rms g min |
N/A N/A N/A N/A |
|
Frequency range Curve |
N/A N/A |
|