MIL-R-83726/19G
Minimum voltage (over temperature range): 20 V dc. Minimum voltage high-temperature test: 20 V dc. Minimum voltage (continuous current tests): 20 V dc. Maximum coil current at 25°C: 0.150 ampere. Operate time: 25 milliseconds (maximum).
Recycle time: 50 milliseconds maximum (over the total temperature range and with both minimum and maximum input voltages).
Electrical data:
Insulation resistance at 500 V dc: 2/ Initial: 100 megohms (minimum).
After life or environmental tests: 100 megohms (minimum).
Dielectric strength (sea level): 2/
Initial |
After life tests |
|
Coil to case. 3/ |
1,050 V rms |
1,050 V rms |
All other points. 4/ |
1,250 V rms |
1,250 V rms |
Dielectric strength (altitude) (80,000 feet): 2/ 5/
Initial |
After life tests |
|
Coil to case. 3/ |
350 V rms |
350 V rms |
All other points. 4/ |
350 V rms |
350 V rms |
Transients (at terminals X1 and X2):
Transient voltage limits (input): In accordance with MIL-STD-461 (methods CS101, CS114, RS101, and RS103) for PIN's with a suffix letter W. For PIN's with a suffix letter A, the same limits apply except that the field intensity limits for RS103 are as specified in table III. Susceptibility testing shall not cause the relay to change state nor affect the timing interval beyond allowable tolerance limits.
2/ Terminals X1 and X2 are connected together during this test.
3/ Leakage current is limited to 50 microamperes.
4/ Leakage current is limited to 25 microamperes.
5/ Relay is not installed in its bracket and socket assembly (MIL-PRF-12883/51-004).
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business