TABLE I. Operating characteristics.
Oash No |
Type |
Coil data |
Time (milliseconds-maximum) |
|||||||||||||||
Coil |
Nominal |
Max |
Max pick-up voltage |
Hold voltage 21 |
Orop out voltage 21 |
Oper- ate |
Re- lease |
Bounce |
||||||||||
Volts 11 |
Freq. Hz |
Res. n |
Volts |
Amp- eres |
Norm 21 |
High temp test |
Cont. current test |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
|||||||||||||||
-001 |
I |
X1, X2 |
28 |
dc |
30 |
0.6 |
18 |
19.8 |
22.5 |
7.0 |
1.5 |
25 |
10 |
11 CAUTION: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay.
21 Over the temperature range.
31 With nominal coil voltage.
41 From nominal coil voltage.
TABLE II. Rated contact load (amperes per pole) case grounded.
Type of load |
Life operating cycles X 3 10 |
28 V dc |
115 V ac, 1 phase |
1151200 V ac, 3 phase 11 |
See notes |
|||||||||
Main |
Aux |
Main |
Aux |
Main |
Aux |
|||||||||
NO |
NC |
NO |
NC |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
400 Hz |
60 Hz |
|||
Resistive |
50 |
50 |
50 |
5 |
5 |
|||||||||
Inductive |
30 |
25 |
25 |
5 |
5 |
|||||||||
Motor |
||||||||||||||
Lamp |
50 |
10 |
10 |
.5 |
.5 |
|||||||||
Transfer load |
21 |
|||||||||||||
Mechanical life reduced current |
100 |
12.5 |
12.5 |
|||||||||||
Mixed loads |
11 Absence of value indicates relay is not rated for 3-phase applications.
21 Transfer load indicates the relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.