MIL-R-5757/8F
Life test requirements:
High level: 100,000 cycles at rated load. Minimum current: Level II, 50,000 cycles.
Verification:
Periodic inspection: Groups B and C inspections are not applicable. Group A.
1. Subgroup 1: This subgroup may be waived at the discretion of the qualifying activity if fully tested
MIL-PRF-39016/6 relays are used internally.
2. Subgroup 2: 100 percent.
3. Dielectric withstanding voltage:
(a) Tests to be conducted at sea level rating only.
(b) Duration of application: 5-10 seconds at a 10 percent increase in the dielectric strength voltage.
Qualification inspection. Single submission only is applicable. The qualification sample size shall be 17 units including one open unit. The sample units shall be subjected to all specified tests of the qualification inspection table.
Part number: M5757/8-002.
TABLE I. Part number and characteristics.
Part number M5757/8 |
Coil chamber |
Sealing means |
002 |
Sealed |
Weld |
Supersession data: See table ll.
TABLE II. Supersession data.
Superseded type designation |
Superseding part number M5757/8- |
RY4LA3B3L01 RY4LA1A3L01 RY4LA1B3L01 RY4LA2A3L01 RY4LA2B3L01 RY4LA3A3L01 |
002 |
5