QUALIFICATION: See table II.
MIL-R-5757/23M
TABLE II. Qualification inspection and sample size.
Single submission |
Group submission |
|
36 units plus 1 open unit. Qualification inspection as applicable. |
M5757/23-026 M5757/23-042 M5757/23-002 M5757/23-011 M5757/23-016 M5757/23-032 |
36 units plus 1 open unit Qualification inspection, as applicable. 2 units each part number. Qualification inspection, group I plus shock, vibration, terminal strength, and seal 1/ 2 units each part number. Qualification inspection table, group I |
1/ Tests shall be performed in order shown.
CONFORMANCE INSPECTION:
Group A inspection: Applicable (subgroups 2 and 3) except dielectric withstanding voltage, 5-10 seconds at 10 percent increase in dielectric strength test voltage.
Group B inspection: Applicable. Group C inspection: Not applicable
SUPERSESSION DATA: See table III.
TABLE III. Supersession data.
Superseded PIN M5757/23- |
New PIN M5757/23- |
021 022 023 024 025 035 |
026 027 028 029 030 036 |
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business