MIL-R-5757/103E
Part number: M5757/103- (dash number from table I).
TABLE I. Dash number and characteristics. 1/
Dash number 2/ |
Coil voltage V dc |
Mounting configuration |
Pick-up voltage (max V dc at 25°C) |
Drop-out voltage (V dc at 25°C) |
Coil resistance (Ohms ±10 at 25°C) |
Weight (max ounces) |
|
Rated |
Max |
||||||
001 |
12 |
15 |
No mount |
7 |
5.5 to 0.8 |
500 |
0.15 |
002 |
12 |
15 |
Bracket mount |
7 |
5.5 to 0.8 |
500 |
0.18 |
003 |
16 |
21 |
No mount |
10 |
8.2 to 1.0 |
1,000 |
0.15 |
004 |
16 |
21 |
Bracket mount |
10 |
8.2 to 1.0 |
1,000 |
0.18 |
005 |
26.5 |
32 |
No mount |
14 |
10 to 1.5 |
2,000 |
0.15 |
006 |
26.5 |
32 |
Bracket mount |
14 |
10 to 1.5 |
2,000 |
0.18 |
1/ Each relay possesses high-level and low-level capabilities. Relays tested to high-level characteristics are not recommended for subsequent use in low-level applications.
2/ Original equipment manufacturers should be aware that these dash numbers are produced in either header style, depending upon suppliers, indicated in figure one.
TABLE II. Qualification inspection and sample size.
Single submission |
Dash no. |
Group submission |
12 units plus 1 open unit qualification inspection as applicable |
005 004 001 |
12 units plus 1 open unit qualification inspection as applicable 2 units qualification, group 1, also shock, vibration, acceleration, terminal strength, seal and resistance to soldering heat Qualification inspection group 1 |
Conformance inspection, Periodic inspection: Group C tests not applicable.
Custodians: Preparing activity: Army - CR DLA - CC Navy - EC
Air Force - 11 (Project 5945-1333) DLA - CC
Review activities: Air Force - 99
Navy - AS, MC, OS, SH
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business