MIL-PRF-83536/24A
Bend: Applicable.
Twist: Applicable.
Socket pin terminals:
Pull force:
For .040 diameter terminals: 5 pounds ±0.5 pound.
For .062 diameter terminals: 10 pounds ±0.5 pound.
Bend: Applicable.
Twist: Not applicable.
Terminal solderability: Applicable to solder pin and solder hook terminals only.
Seal: Hermetic.
Marking: Applicable.
Part or Identifying Number (PIN): M83536/24 (dash number from table III and suffix letter designating failure rate
level).
Qualification inspection:
Qualification inspection and sample size: See table IV.
TABLE IV. Qualification inspection and sample size. 1/
Single submission
Group submission
M83536/24-022
18 units plus 1 open unit
18 units plus 1 open unit
for level L at C = 0 2/
for level L at C = 0 2/
33 units plus 1 open unit
M83536/24-022
33 units plus 1 open unit for level
for level M at C = 0 2/
M at C = 0 2/
Qualification inspection
M83536/24-022
Qualification inspection as
as applicable
applicable
M83536/24-018
2 units, qualification inspection
M83536/24-023
table, Q2, shock, vibration,
acceleration, terminal strength,
and seal
M83536/24-002
2 units, qualification inspection
M83536/24-014
table, Q1
M83536/24-031
1/ For retention of qualification or extension of qualification to lower failure rate levels, all life
test data accumulated on MIL-PRF-83536/25 may be used in addition to MIL-PRF-
83536/24 data. Prior to performance of retention of qualification testing, the relay
manufacturer shall preselect the sampling plan.
2/ The number of units required for qualification testing shall be increased as required in
Q5, table II of MIL-PRF-83536, if the contractor elects to test the number of units
permitting one or more failures. Prior to performance of qualification testing, the relay
manufacturer shall preselect the sampling plan.