MIL-PRF-6106/40D
REQUIREMENTS
CONTACT DATA
Life: Unless otherwise specified, 50,000 cycles.
Load ratings:
High level (relay case grounded).
Resistive: 10 amperes at 28 V dc, 115 V ac, 400 Hz, 1 phase, 115/200 V ac, 400 Hz, 3 phase.
Inductive: 6 amperes at 28 V dc (life, 10,000 cycles), 8 amperes at 115 V ac, 400 Hz, 1 phase, 115 V ac,
400 Hz, 3 phase (life, 20,000 cycles).
Motor: 4 amperes at 28 V dc, 115 V ac, 400 Hz, 1 phase; and 115/200 V ac, 400 Hz, 3 phase.
Lamp: 2 amperes at 28 V dc and 115 V ac, 400 Hz, 1 phase.
Low level: 10 to 50 A at 10 to 50 mV dc or peak ac. 1/ 2/ 3/
Intermediate current: Applicable.
Transfer load: Not applicable.
Mechanical life (reduced current): 1.25 amperes at 28 V dc, 115 V ac, 1 phase and 3 phase (life, 200,000
cycles)
Mixed loads. Applicable. 4/
Contact voltage drop or resistance. 1/ 2/ 3/
High level:
Initial; 0.150 volt maximum.
After life; 0.175 volt maximum.
Low level:
Initial; 0.050 ohm maximum.
After life; 0.150 ohm maximum.
Contact bounce: 1.0 millisecond maximum.
Break bounce (normally open contacts only): 0.1 millisecond maximum (applicable to dc suppressed coils only).
________
1/ For low level, the following shall apply:
a. During endurance and operational reliability testing, contact load shall be 10 to 50 microamperes, 10 to
50 millivolts open circuit voltage, 100 ohms maximum contact resistance.
b. Static contact resistance shall be performed at 50 mA maximum, 50 mV maximum.
2/ For all ER relays, the alternate low level test of operational reliability shall be used.
3/ For group A contact voltage drop test, high level testing shall be performed first, followed by low level testing.
The contacts shall not make or break the high level load.
4/ Relay shall be capable of switching low level while switching any of the other rated loads on adjacent contacts.
7