TABLE I. Dash number and operating characteristics.
Coil data
Time milliseconds-maximum
Dash
Type
Nominal
Maximum
Max pickup voltage 1/
Hold
Drop
Bounce
no.
Coil
voltage
out
Operate
Volts
Freq
Res
Volts
Ampere
Normal
High
Cont
Main
Auxiliary
voltage
temp
current
Inrush
Steady
NO
NC
NO
NC
test
test
state
-001
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
-
2
-
-
-002
1
X1, X2
28
DC
-
29
1.25
.25
17
20
21.5
7.0
1.5
25
25
-
2
2
2
-003
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
55
35
-
2
-
-
-004
1
X1, X2
115
400
-
124
.71
.1
85
95
100
40
10
55
35
-
2
2
2
1/ Over the temperature range
2/ With nominal coil voltage
3/ From nominal coil voltage
TABLE II. Rated contact load (amperes per pole) (case grounded).
Life
28 V dc 1/
115 V ac, 1 phase 1/
115/200 V ac, 3 phase 1/
Type of
operating
Main
Auxiliary
Main
Auxiliary
Main
Auxiliary
load
cycles
NO
NC
NO
NC
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
x103
Resistive
100
-
-
3
3
60
-
3
-
60
-
-
-
Inductive
100
-
-
1.5
1.5
60
-
1.5
-
60
-
-
-
Motor
50
-
-
-
-
40
-
-
-
40
-
-
-
Lamp
-
-
.5
.5
-
.5
-
-
-
-
Transfer
-
-
-
-
-
-
-
load 2/
Mechanic
200
-
-
.75
.75
15
-
.75
-
15
-
-
-
al life
reduced
current
Mixed
50
-
-
Per spec
4
-
-
-
4
-
-
-
loads 3/
1/ Absence of value indicates relay is not rated for that application.
2/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating.