TABLE I. Dash numbers and characteristics. 1/
At 25°C
Dash number 2/
Over temperature range
Coil voltage (V dc)
5/
Lead
Lead
Coil
Lead
Speci-
Spreader
Speci-
Speci-
Speci-
Speci-
Speci-
length
fied
mounting
fied
length
fied
length
resist-
fied
fied
fied
1.500
.187
Rated
Max
ance
.500
pickup
pads
hold
dropout
pickup
hold
dropout
±.010
min
ohms
min
value
(fig. 2)
value
value
value
value
value
±10%
3/
4/
(voltage) (voltage) (voltage) (voltage)
(voltage)
(voltage)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
(V dc)
017
025
033
041
5.0
7.5
100
2.6
1.4
0.23
3.5
2.5
0.12
018
026
034
042
6.0
10
200
3.4
2.0
0.28
4.5
3.2
0.18
019
027
035
043
12
20
850
7.0
4.0
0.64
9.0
6.5
0.41
020
028
036
044
26.5
40
3,300
14.0
8.0
1.4
18
13
0.89
021
029
037
045
36
57
6,500
20
10
1.8
27
19
1.25
022
030
038
046
48
75
11,000
25.8
13
2.4
36
26
1.60
023
031
039
047
9
15
400
4.85
3.0
0.55
6.8
4.9
.35
024
032
040
048
18
30
1,600
9.8
6.0
0.92
13.5
10
0.59
1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 mA resistive at 6
V dc maximum or peak ac open circuits not recommended for subsequent use in low level applications.
2/ The suffix letter L, M, P, or R, to designate the applicable failure rate level, shall be added to the applicable listed dash number.
Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. Example, 017L - - - - - - -24R.
3/ 1.500 leads are inactive for new design.
4/ Relays supplied with spreader mounting pads (-041 through -048) shall have the spreader mounting pad rigidly attached.
5/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business