MIL-PRF-39016/10G
Qualification inspection (reduced testing) and sample size: See table III.
If the relays produced for MIL-PRF-39016/10 are similar in construction and design except for the diodes, and
headers, as applicable, to the relays produced for MIL-PRF-39016/11, /16, /21, /25, or /26, then reduced testing
for qualification of MIL-PRF-39016/10 relays may be performed concurrent with or subsequent to successful
qualification of MIL-PRF-39016/11, /16, /21, /25, or /26. For reduced testing, see table III.
TABLE III. Qualification inspection (reduced testing).
Inspection
2 units each coil voltage Q1 of qualification
inspection table.
1 unsealed sample unit for internal examination.
SUPERSESSION DATA:
Supersession data: See table IV.
TABLE IV. Supersession data. 1/
Superseded
New PIN
Superseded
New part no.
PIN
M39016/10-
PIN
M39016/10-
M5757/69-
2/
M39016/10-
2/
001
019
001
017
002
021
002
018
003
023
003
019
004
025
004
020
005
027
005
021
006
020
006
022
007
022
007
023
008
024
008
024
009
026
009
025
010
028
010
026
011
017
011
027
012
018
012
028
013
029
013
029
014
030
014
030
015
031
015
031
016
032
016
032
1/ Dash numbers -017, -019, -021, -023, -025, -027, -029, and -
031 are inactive for new design and are for support of existing
designs only.
2/ Complete part number shall contain suffix letter L, M, P, or R
to designate failure rate level (see 2/ of table I). A part with
any failure rate supersedes the applicable MIL-R-5757 part.
Cross-reference for Government logistical support: See table V.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business