MIL-F-26301G
TABLE II. First article inspection.
Number of
Inspection
Requirement
Test
Number of
allowable
paragraph
paragraph
sample flashers
to be inspected
failures
Group I
Visual and mechanical
examination (external)
and 3.19
All flashers in
1
sample
(13 total 1/ )
Flash characteristics
Voltage drop
Group II
High and low temperature
soak and operation.
3
1
Vibration
Immersion
Group III
Shock
Altitude
Humidity
3
1
Salt fog
Sand and dust
(when specified)
Group IV
Electromagnetic interference
2
0
Transient voltage
Group V
Life
0
4
1/ One additional flasher is included in the sample to allow for the one defective flasher allowed for group I.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744