AN3314
REVISION 3
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance are ±.016 (0.040 mm), angles ±5°.
FIGURE 1. Configurations and dimensions - Continued.
REQUIREMENTS
Operating cycles: 50,000 minimum.
Contact data:
Contact voltage drop: Not applicable.
Load ratings: See Table I.
TABLE I - Rated contact load (per pole).
Type of load
Amperes
Resistive (DC)
10
Inductive
10
Motor
6
Overload current: Not applicable.
Rupture current: Not applicable.
Coil data:
Nominal coil voltage: 28 volts.
Maximum operating voltage: 29 volts.
Pickup voltage: 18 volts.
Hold voltage: 7 volts
Dropout voltage: 1.5 volts.
Rated duty: Continuous.
Coil current: 0.2 amperes, maximum.
Physical data:
Weight: 0.4 pounds, maximum.
Qualification by similarity: See MIL-PRF-6106.
2