AN3310
REVISION 5
Inches
mm
.016
0.040
2.125
5.400
2.219
5.646
2.406
6.112
3.125
7.938
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance are ±.016 (0.040 mm).
FIGURE 1. Configurations and dimensions - Continued.
REQUIREMENTS
Operating cycles: 50,000 minimum.
Contact data:
Contact voltage drop:
Initial: 0.150 volt maximum. Applicable only for AN3310-2.
After life: 0.175 maximum. . Applicable only for AN3310-2.
Load ratings: See Table I.
TABLE I - Rated contact load (per pole).
Type of load
Amperes
Resistive (DC)
10
Resistive (AC 400 Hz, 115 volts)
10
Inductive
10
Motor
6
Overload current: See MIL-PRF-6106. Not applicable to AN3310-1.
Rupture current: See MIL-PRF-6106. Not applicable AN3310-1.