AN3308
REVISION 6
AN Part Number
A (MAX)
B (MAX)
AN3308-1
2.094
1.718
AN3308-2
2.188
1.813
Inches
mm
.016
0.040
1.719
4.366
1.813
4.604
2.094
3.094
2.188
5.556
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance are ±.005 (0.013 mm).
FIGURE 1. Configurations and dimensions - Continued.
REQUIREMENTS
Operating cycles: 50,000 minimum.
Contact data:
Contact voltage drop:
Initial: 0.150 volt maximum. Applicable only for AN3308-2.
After life: 0.175 maximum. Applicable only for AN3308-2.
Load ratings: See Table I.
TABLE I - Rated contact load (per pole).
Type of load
Amperes
Resistive (DC)
10
Resistive (AC 400 Hz, 115 volts)
10
Inductive
10
Motor
6
Overload current: See MIL-PRF-6106. Not applicable to AN3308-1.
Rupture current: See MIL-PRF-6106. Not applicable AN3308-1.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business